Cmu Wall Vapor Barrier
Perm a barrier npl 10 npl 10 lt membrane is vapor impermeable and provides superior protection against the damaging effects of air and liquid water ingress on building structures.
Cmu wall vapor barrier. Concrete block wall systems are also quite common on job sites. In warm moist climates install the vapor barrier on the cavity surface of the outer wythe figure 4. This wall assembly will dry from the vapor barrier inwards and will dry from the vapor barrier outwards. The mass of the concrete is able to absorb any moisture generated by vapor traveling through the assembly and will dry out before it reaches 80 relative humidity.
Mass walls behave differently from other structural systems such as wood or steel. In any case the vapor barrier must point to the warm side. For general use pre insulated cmu mass walls don t require a vapor barrier. Vapor barrier will drain through the brick wythe s weep holes.
Fluid applied air water resistive barrier and water vapor barrier description vb is a fluid applied air and water resistive barrier that stops air and water leakage in cavity wall masonry veneer construction as well as in stucco eifs and most other building wall assemblies. Thus installing vapor barriers on wall surfaces must. This barrier is meant to keep moisture from getting to the insulation in the walls and ceilings and it is required by building codes when insulating most houses. On double wythe masonry walls with an insulated wall cavity constructed in cold climates the vapor barrier should be installed on the cavity surface of the inner wythe figure 3.
The air and water barriers most commonly used on a wall system are fluid. Vapor barriers are sheets of plastic or other material placed on one side of insulation sheets. The science of moisture movement. Whether or not you need a vapor retarder hinges on three main factors.
Water vapor can pass through building materials in several ways including direct transmission and by heat transfer but studies suggest that fully 98 percent of the moisture transfer through walls occurs through air gaps including cracks around electrical fixtures and outlets and gaps along baseboards. A vapor retarder is a material used to prevent water vapor from diffusing into the wall ceiling or floor during the cold winter. Not every wall does. You can use a spray a roller or a brush to apply the liquid barrier.
Most masonry projects often have horizontal joints reinforcing the wall along with masonry wire tires that extend out of the joints.