Cold Deck Flat Roof
The insulation boards in an inverted warm deck are laid over the structural deck and the waterproof covering.
Cold deck flat roof. The solution warm deck insulation. Where a cold flat roof does incorporate insulation this is. Firstly there are two types of flat roof. This system is called warm deck insulation and eradicates the condensation and venting issues associated with the cold deck system.
The epdm rubber roof membrane is then installed using the contact adhesive onto the deck. The breakdown warm roof vs cold roof. A warm roof and a cold roof. Contrasted with the cold deck roof this construction has a much lower risk of condensation as the void will be of a comparable temperature to the roof.
Warm roof insulation ensures the entire roof structure is insulated meaning a warm deck roof is more energy efficient than a cold roof. The layer of insulation is essentially placed outside of the roof. The underside of the rafters in this case will need to be finished with a suitable vapour control layer vcl and plasterboard to provide a suitable internal finish to the roof. The sandwich warm deck roof is the most common type of flat roof.
Traditional cold deck flat roof. Fortunately these days there is a better form of insulation available for your flat roof. This is known as a cold roof because the roof deck and roof space are close to the external air temperature. Traditionally flat roofs simply consisted of a structural timber deck with a waterproof covering directly applied to the top of the deck.
The insulation is placed below the waterproof covering and is either mechanically fixed or bitumen bonded on to the top of the deck. The 18mm roof grade deck is then fixed on top of the rafters leaving suitable air flow between the insulation and the deck. This design dates back many years and flat roof insulation was somewhat of an afterthought with this type of roof. A ventilation gap usually 50mm should be provided between the top of the insulation and underside of the roof covering to allow the air to flow across.
Ventilation openings either at. Condensation occurs when warmer moist air meets colder surfaces. The insulation in a warm deck roof is installed immediately below the roof membrane on top of the roof deck usually with a vapour control layer underneath the insulation. Inverted warm deck roof.
A cold flat roof insulation requires more work taking off old boards and replacing them and the roof surface. A warm roof is defined as being when the all or the majority of the insulation is above the joists or deck. Alternatively battens can be secured to the underside of the joists and gmw fitted between these in much the same way as between the main roof joists.