Copper Refrigeration Tubing Wall Thickness
Wall thickness type k l m dwv k l m dwv 1 4 0 375 0 305 0 315 0 035 0 030 3 8 0 500 0 402 0 430 0 450 0 049 0 035 0 025 1 2 0 625 0 527 0 545.
Copper refrigeration tubing wall thickness. Seamless copper tube according astm b280 standard specification for seamless copper tube for air conditioning and refrigeration field service is intended for use in the connection repairs or alternations of air conditioning or refrigeration units in the field. External surface sq ft per linear ft. Dimensions and physical characteristics of copper tube. Acr copper tubes is used in the air conditioning and refrigeration field service industry and is produced in straight lengths.
Copper tubing is most often used for heating systems and as a refrigerant line in hvac systems. Wall thickness search wall thickness. View more view all jump to. Copper tube for air conditioning and refrigeration field service acr is designated by actual outside diameter.
Copper tubing size chart astm b 88. But for normal in the wall household plumbing type m copper pipe is just fine. Diameters depend on tube size and wall thickness. Copper tubing size chart.
All inside diameters depend on tube size and wall thickness. Type l straight copper tubing. Temper describes the strength and hardness of the tube. Design specifications for copper tube tubing types and standards based on astm b88 type k l and m size wall thickness and weight specifications.
In the piping trades drawn temper tube is often referred to as hard tube and annealed as soft tube. Copper tubing is slowly being replaced by pex tubing in hot and cold water applications. Type k copper pipe. There are two basic types of copper tubing soft copper and rigid copper.
Cross sectional area of bore sq inches. Temper describes the strength and hardness of the tube. Copper tubing hvac size chart size and physical characteristics of copper tube. You may be surprised to find two types of copper pipe on the home center shelf type l and type m.
Acr air conditioning and refrigeration field service a annealed temper d drawn temper. Standard copper tubing dimensional reference. Type acr coiled copper tubing. Type m straight copper tubing.
Type l copper pipe is recommended where you need strength and protection. The difference is the wall thickness of the copper pipe sizes and therefore the. Pipe wall thickness varies according to the pipe diameter. Lightweight copper pipe and tubing resists corrosion and is suitable for plumbing refrigeration and hvac applications.
Inch type k pipe has a wall. Copper tubing is joined using flare connection compression connection pressed connection or solder. Type k tube has thicker walls than type l tube and type l walls are thicker than type m for any given diameter.